A pharmaceutical plant prints labels at every step: on starting materials at goods receipt, on containers in production, on every pack on the packaging line, on clinical trial supplies and on the pallets that leave.

Most of them have a rule of their own, and the system that prints them is a computerised system under Annex 11.

The rule

The rules for the system and for the pack have their own pages:

The labels on materials, in production and on the packaging line fall under EU GMP Part I, Chapter 5, Production, in operation since 1 March 2015.

On materials and in production

  • A starting material label carries at least the name and internal code, the batch number given at receipt and, where appropriate, the status (quarantine, on test, released, rejected) and the expiry or retest date (5.32).
  • Where a fully computerised warehouse system holds that data, the label need not show all of it legibly (5.32). The status can then live in the system and be read by scanning.
  • Containers, major equipment and, where appropriate, rooms carry the product, its strength where applicable, the batch and, where applicable, the production stage (5.12), in your agreed format, with colours for the status if you use them (5.13).

On the packaging line

  • Every printing operation, such as code numbers and expiry dates, is checked and recorded (5.55).
  • Roll-fed labels are normally preferred to cut labels, to avoid mix-ups (5.56).
  • Code readers and label counters are checked to work correctly (5.57).
  • Printed labels in stock are kept secure, and obsolete ones are destroyed with a record (5.46 to 5.48). Printing on demand from blank stock leaves far fewer printed labels to lock away.
  • Printed packaging material is reconciled against the packs produced, and an unusual difference is investigated before release (5.61).

On clinical trial supplies

Regulation (EU) No 536/2014, Annex VI, as amended in 2022, sets what the label of an investigational medicinal product carries, including the trial reference code, the subject or treatment number, "For clinical trial use only" and the expiry or retest date in month and year. Each country sets the label language (Article 69).

Where the protocol justifies it, some particulars may be held in the trial's central electronic system instead of on the label. Those that always stay on the label include the batch, the subject or treatment number and the expiry date.

We have set up label printing for clinical trial supplies.

The label materials

The label may have to survive freezer storage, an autoclave cycle, an alcohol wipe down or a cleanroom. And 5.58 asks for print that resists fading and erasing, which depends on the label material and the ribbon together, never on one alone.

  • Tell the what the label must survive, and it gives you a material and a ribbon that fit your printer.
  • Or browse , for deep freeze, autoclave and cleanroom, and .
Filling needles dispensing into vials in a laboratory, a barcode label on a tube

The systems

  • From SAP or your MES: TEKLYNX SENTINEL prints goods receipt, production and dispatch labels from the data your system sends, see 3.1 SAP label printing and 3.2 Systems and interfaces.
  • On the packaging line: print and apply, with a scanner that pushes off a pack whose code does not read and a log of every printed and rejected label, see 3.4 Labeling industrial automation. The scanner is the code reader 5.57 asks you to check, and the log feeds the reconciliation of 5.61.
  • Version control and approval of every template, with an audit trail: 4.4 TEKLYNX LABEL ARCHIVE, or 4.5 TEKLYNX CENTRAL with approval by electronic signature.
  • Qualification: IQ and OQ support for TEKLYNX software and Zebra and cab printers, on 1.4.

What stays with you

  • Your label formats and status colours, your line clearance and your reconciliation limits.
  • Approving each template and each change under your change control, as set out in 1.3.
  • For clinical trials: the label text for each country, and the randomisation data behind it.

An illustrative example

Illustrative: written to show how the parts fit together. It is not a real project or a real customer, and its figures are not results.

A Swiss pharmaceutical packaging site types batch numbers and expiry dates from SAP screens into its label templates by hand. Once SAP sends the data, TEKLYNX SENTINEL prints it on CODESOFT templates approved in LABEL ARCHIVE, on Zebra printers, with IQ and OQ support from us.

Labels typed by hand: from about 400 a week to none.

The longer version: A.3 Illustrative examples

Last checked: 21 October 2026.

Start with the free half-day review of your current label print chain: [email protected].